- unscrew and remove the tank cap...
- take the filter out of the tank
- remove all the working fluid from the reservoir using a tool suitable for this (syringe, pear), then screw the lid on the tank to prevent dirt from getting inside
- Then, lifting the tank up, remove it from the bracket fixed on the body
- with a suitable tool, loosen the hose clamps by squeezing their petals and sliding them down the hose
- remove the hoses from the tank fittings and remove the tank itself
Installation is in the reverse order. After installation, bleed the system.