Injector rail: 1 - nozzle retainer; 2 - ramp; 3 - nozzle; 4 - nozzle sealing ring; 5 - fitting for connecting the high pressure fuel line
Torque
- Fuel manifold bolts - 9 Nm
Removing
Attention! When removing the fuel manifold and injectors, some fuel may leak. Take measures to protect the generator from fuel.
1. Disconnect the battery.
2. Remove the fuel manifold protection.
3. Without pinching the fuel supply hose (1) Loosen the hose connection to the manifold.
4. Disconnect the injector connectors (2) and knock sensor (3).
5. Remove the bolts (4) fuel manifold mountings.
6. Remove the fuel manifold along with the injectors.
7. Remove nozzles. Discard the O-rings.
Installation
Installation is carried out in the reverse order. After installing the injectors, check the correct installation of the sealing rings. Secure the nozzles with clips.