Contents: Removal 🠛 Installation 🠛
Removal
- disconnect the stepper motor controller connector;
- remove the crankcase ventilation hose;
- unscrew the three regulator mounting bolts.
Installation
Installation is performed in the reverse order of removal. When installing, observe the tightening torques of the three mounting bolts. Check the condition and ensure that the sealing ring is installed correctly.