Removing
Place the car on a two post lift.
Disconnect the wires from the battery terminals, starting with the negative terminal.
Use the filling station to drain the refrigerant circuit from the filling station.
Remove the front bumper.
Remove the front body panel
Pic. 8.156. Piping Bolt: 1 - bolt
Loosen the bolts securing the piping to the condenser (pic. 8.156).
Disconnect the pipelines.
Insert plugs into all holes.
Remove the condenser.
Installation
Installation is made in an order, the return to removal.
Check the security of the condenser.
Replace seals.
To facilitate the installation of pipelines, grease their ends with oil used for the air conditioning system.
Tighten the piping bolts (10 Nm).
Note. After replacing the condenser, fill the new condenser with oil equal to the amount drained and add 30 ml of the specified oil.
Charge the refrigeration circuit with refrigerant using a filling station. Gas station
Note. Check the operation of the air conditioning system with the electric fan running at maximum speed.
Search for leaks.