Removing
After removing the inner lining, remove the two glass mounting clips A, disconnect the glass from the axes of the power window slider.
Raise the glass manually and secure it with protective tape.
Remove the five mechanism mounting bolts B (MB head for 10).
Disconnect the power connector.
Remove the power window through the bottom opening in the door frame.
Installation
Installation is made in an order, the return to removal.
Power window motor initialization
Set the card in the reader to the 2nd fixed position.
Close the glass up to the top (glass rises with intermittent movements).
Keep the switch pressed (about two seconds).
Lower the glass to the bottom stop, keep the switch pressed.
The motor has been initialized.