Contents: Removal 🠛 Installation 🠛
Removal
- Removal the pressure regulator requires removing the intake manifold, as well as the turbocharger heat shield.
- Remove the intake manifold and heat shield.
Fig. 3.45. Location of collector heat-insulating screen mounting bolts
- Remove the air duct.
- Remove the oil supply pipe.
- Remove the retaining ring on the pressure regulator rod.
- Remove the 2 bolts securing the pressure regulator support.
Installation
- Apply the product to the threads of the pressure regulator support mounting bolts "Loctite Frenbloc" and tighten the bolts to a torque of 15 Nm.
- Install the upper coolant supply pipe and check the condition of the gaskets. Replace the gaskets if necessary.
- To install the pressure regulator rod, use tool Mot. 1014.
(Original publication on the portal: renaultbook.ru)