Install the MS 554-06 fixture on the MS 554-07 pump, then install the valve to be tested on the fixture
Increase the pressure. It should stabilize at the valve opening pressure. Control tolerance ±0.1 bar.
Valve opening pressure
| Engine | Valve color | Opening pressure, bar |
| All models | Brown | 1.2 |