| Resistance when measured between contacts A1 and B1, Ohm | Height H, mm |
| 7 no more | 180 |
| 55±7 | 146 |
| 98±10 | 114 |
| 155±16 | 75 |
| 33±20 | 33 |
Make sure that the resistance changes as you move the float.
Measuring height H
Place the removed sensor on a flat surface. H is the height measured between the float axis and the working plane
Note: All values given are for reference only.
Fuel level sensor connector pin assignment
| Contact number | Name |
| A1 | Fuel level sensor "+" signal |
| A2 | Not used |
| B1 | Fuel level sensor "-" signal |
| B2 | Not used |
| C1 | "+" Fuel pump |
| C2 | "-" Fuel pump |