Resistance when measured between pins A1 and B1. Ohm | Height H, mm |
7 no more | 180 |
55±7 | 146 |
98±10 | 114 |
155±16 | 75 |
33±20 | 33 |
Make sure the resistance changes as the float moves.
Height measurement H
Place the removed sensor on a flat surface. H - height measured between the axis of the float and the working plane
Note. All values shown are for reference only.
Pin assignment of the fuel level sensor connector
Contact number | Name |
A1 | Signal «+» fuel level sensor |
A2 | Not used |
IN 1 | Signal «-» fuel level sensor |
AT 2 | Not used |
C1 | «+» Fuel pump |
C2 | «-» Fuel pump |