Caution: Perform the inspection procedure with the engine off.
Remove the cover of the protection and switching unit.
Disconnect the brown connector of the protection and switching unit (2).
Connect the brown connector contact (3) to the "+" terminal of the battery to operate the fuel pump.
Wiring diagram for devices when checking an electric fuel pump:
1 - pipeline with pressure gauge;
2 — "tee" of the device (Mot. 1311-08);
3 — fuel supply line.
![]() |
![]() |
(Original publication on the website RenaultBook.ru)
Measure the pump capacity, which should be 80-120 l/h.