Examination
1. Connect a vacuum gauge to the vacuum pump and start the engine. The pump, with the engine warmed up to operating temperature and running at 4000 rpm, should produce at least 700 mbar of pressure after three seconds.
Removal
2. Unscrew the vacuum pump mounting bolts and remove it (see illustration).
11.2 Unscrew the vacuum pump mounting bolts and remove it
You can find the original at this link: renaultbook
Installation
3. Install the vacuum pump 16 in place, replacing the old sealing gasket with a new one (see illustration).
Attention! When replacing the vacuum pump, it is necessary to replace the cam 58 with a new one (see illustration 11.3).
11.3 Install the vacuum pump 16 in place, replacing the old sealing gasket with a new one. 59 - vacuum pump mounting flange