Set the multimeter to «ohmmeter».
Turn the multifunction switch manually until the switch closes (resistance on switch contacts 0 Ohm).
Torque tighten (10 Nm) multifunction switch mounting bolts.
Attention! After tightening the bolts, the electrical contact must be closed (0 ohm).
Check system operation and gear shifting.